The Randell BC series blast chillers are designed for rapid chilling through the
danger zone down to 40 or below in approximately 90 minutes. The exact chill time
will vary depending on product type.
The door must be in closed position to activate switch at top of door before any
cooling cycle will begin.
1. Introduction
The control software for the BC Control Unit is based on a “Real-Time
Operating System and is capable of simultaneously running a chiller operation
while at the same time accepting/displaying user information from the control
panel such as chiller preset adjustments. This document provides an overview
of the current controller features.
2. Status LED Indicator Conventions
a. Safe/Temp LED indicators (Probes 1 through 4, and Air)
i. Flashing – Indicated probe currently displayed and used for set point
control
or a temperature alarm indication.
ii. Solid – Indicated probe has reached the “Safe” set point or purposely
selected
for display monitoring.
iii. Solid Momentary – Indicated probe’s temperature currently
displayed.
b. Mode LED Indicators
i. Solid – Identifies the selected mode that will be run if the Start/Stop
Key is
depressed.
ii. Flashing – The indicated mode is in operation.
3. Powering Up Unit
a. The unit once connected to AC power will turn on for a short period.
An LED illumination test will be performed, followed by the display of
the software version number. The unit will then blank the display and
go into a standby mode. The unit will remain in a standby until the
On/Off key is depressed.
b. Depressing the On/Off key will cause the unit to become active and
enter the Idle mode. Refer to Idle Mode operation below.
4. Powering Down Unit
a. The unit may be returned to the low power standby state by
depressing the On/Off
key. The display will then go blank while powered down. The unit may
be restarted